In this guide
A pool heat pump works like an air conditioner in reverse. It pulls heat from the air, and it pulls water out of the air too. Gallons of water under a heat pump on a humid day can be normal.
The test
- Turn off the heat pump, but leave the pool pump running.
- Wait a few hours.
- If the water stops, it was condensation.
- If water keeps coming, it is a leak.
Another test
Test the water under the unit with a pool test strip. Condensation has no chlorine. Pool water does.
Real leaks
Unions, the water connections and the heat exchanger can leak. The exchanger is usually titanium and lasts, but freezes can damage it.
Send a photo by text to (469) 277-9893 and we can usually tell you which one it is.