What HP means on an AquaCal heat pump
The high pressure switch in the refrigerant circuit has opened.
The code stays on the display until the cause is fixed, and the compressor will not run while it shows.
What causes HP
- Low water flow through the heat exchanger
- A failed high pressure switch
- Faulty wiring to the switch
What you can check yourself
- Check the pump is on and the valves send water through the heat pump
- Clean the filter
- Raise the pump speed if it is variable speed
If the water flow is good and HP returns, the switch or the refrigerant circuit needs testing.
Never open the cabinet with the power on. A heat pump has high voltage and refrigerant under pressure inside.
How we fix an AquaCal HP
- We read the code and the historyAnd ask what the weather and the pump were doing when it showed.
- We test, with a meter and gaugesWater flow, the sensors, the switches and the refrigerant pressures, so the part we quote is the part that failed.
- You get the price in writingBefore any part is fitted.
- We repair it and run itAnd watch it through a full heating cycle before we leave.
What it costs
| Service | Price |
|---|---|
| Diagnostic visit: Monday to Saturday, 7 a.m. to 7 p.m. | $149 |
| Emergency service call: 7 p.m. to 7 a.m., all day Sunday, and holidays | $299 |
| The repair itself | written price before work starts |
When the repair or replacement is over $1,000 and you approve it while we are there, the $149 goes toward it. On jobs under $1,000 it does not.
Other AquaCal codes
- FLO: low or no water flow
- LP: refrigerant low pressure
- LP5: five low pressure faults: locked out
- HP5: five high pressure faults: locked out
- OTA: over temperature alarm
- FS: defrost mode
- dPO: defrost sensor open
- dPC: defrost sensor shorted
- PO: water temperature sensor open
- PC: water temperature sensor shorted
- CSE: control system error
- CEr: communication fault
AquaCal HP questions
Can I keep using the heat pump with HP showing?
It will not heat while the code shows. Do the checks above once. If it comes back, leave it off and book a visit.
Will turning the power off and on clear HP?
Only for a moment. The code is reporting something real, and it comes back until that is fixed.
Do you repair AquaCal heat pumps?
Yes, across Dallas–Fort Worth and in the Austin and Houston areas.
Local teams in Dallas–Fort Worth, Austin and Houston
Teams work from Frisco, Plano, Fort Worth, Arlington, Cedar Hill, Austin and Houston, so a PoolBurg truck is never far from your pool.


Book a visit