What LP5 means on an AquaCal heat pump
The heat pump has had five low pressure faults in one call for heating or cooling and has locked itself out to protect the compressor.
The code stays on the display until the cause is fixed, and the compressor will not run while it shows.
What causes LP5
- Everything that causes LP, happening repeatedly
What you can check yourself
- Turn the power off and back on once to clear the lock
- If LP returns, leave it off
It needs the refrigerant circuit checked. Running it on repeated resets risks the compressor.
Never open the cabinet with the power on. A heat pump has high voltage and refrigerant under pressure inside.
How we fix an AquaCal LP5
- We read the code and the historyAnd ask what the weather and the pump were doing when it showed.
- We test, with a meter and gaugesWater flow, the sensors, the switches and the refrigerant pressures, so the part we quote is the part that failed.
- You get the price in writingBefore any part is fitted.
- We repair it and run itAnd watch it through a full heating cycle before we leave.
What it costs
| Service | Price |
|---|---|
| Diagnostic visit: Monday to Saturday, 7 a.m. to 7 p.m. | $149 |
| Emergency service call: 7 p.m. to 7 a.m., all day Sunday, and holidays | $299 |
| The repair itself | written price before work starts |
When the repair or replacement is over $1,000 and you approve it while we are there, the $149 goes toward it. On jobs under $1,000 it does not.
Other AquaCal codes
- FLO: low or no water flow
- LP: refrigerant low pressure
- HP: refrigerant high pressure
- HP5: five high pressure faults: locked out
- OTA: over temperature alarm
- FS: defrost mode
- dPO: defrost sensor open
- dPC: defrost sensor shorted
- PO: water temperature sensor open
- PC: water temperature sensor shorted
- CSE: control system error
- CEr: communication fault
AquaCal LP5 questions
Can I keep using the heat pump with LP5 showing?
It will not heat while the code shows. Do the checks above once. If it comes back, leave it off and book a visit.
Will turning the power off and on clear LP5?
It clears the lock or the message once. If the cause is still there, the code returns.
Do you repair AquaCal heat pumps?
Yes, across Dallas–Fort Worth and in the Austin and Houston areas.
Local teams in Dallas–Fort Worth, Austin and Houston
Teams work from Frisco, Plano, Fort Worth, Arlington, Cedar Hill, Austin and Houston, so a PoolBurg truck is never far from your pool.


Book a visit